Apnea Test Safety in Brain Death: A Single-Center Retrospective Cohort Analysis

Talita Sansoni, Nicholas Nascimento, Gabriel Franco, Rui Moreno, Alexandre Barros, Venancio Filho, Helder Zambelli, Ana Paula Gasparotto, Luiz Antonio Sardinha, Antonio Luis Falcao

Abstract


Background: The apnea test, which is considered positive when no spontaneous breathing movements are observed following maximal hypercapnia (PaCO2 > 55 mm Hg) respiratory center stimulation, was critically evaluated in this study by assessment of blood gas analyses performed during brain death protocols from 2010 to 2017, in the intensive care units of the Universidade Estadual de Campinas (UNICAMP).

Methods: A retrospective cohort analysis based on the intensive care unit and Transplant Organ Search Organization data banks. Blood gas analyses before (pre-first and -second apnea tests) as after (after-first and -second apnea tests) were assessed. Descriptive statistical analyses of the numerical variables (such as pH, PaO2, PaCO2, HCO3, SatO2) with mean values and standard deviation, medians, and quartiles were performed. The Student’s t-test was used for pairwise group comparisons. A P < 0.05 level was adopted for significance.

Results: Eighty-seven protocols were evaluated. The mean apnea test duration was 11 min. All of the patients were under vasoactive drugs. Only five apnea tests were interrupted before the end at 10 min due to rapid desaturation (SatO2 < 90%), with no invalidated apnea test. Mean and standard deviation of blood gas tests assessed before the first apnea test were: pH 7.35(± 0.10), PaO2 252.15 mm Hg (± 114.11), PaCO2 42.78 mm Hg (± 10.84); after the first apnea test: pH 7.11(± 0.08), PaO2 208.39 mm Hg (± 112), PaCO2 82.43 mm Hg (± 16.91); before the second test: pH 7.33 (± 0.09), PaO2 253.56 mm Hg (± 105.36), PaCO2 43.76 mm Hg (± 9.67); following the second apnea test: pH 7.11 (± 0.10), PaO2 200.1 mm Hg (± 116.45), PaCO2 84.98 mm Hg (± 20.21). The pH, PaO2, and PaCO2 values before and after the first and second apnea tests have shown statistically significant differences (P < 0.0001).

Conclusions: The apnea test was safe, blood gas test results are similar to those described in the literature, severe hypoxemias were prevented by a quick reconnection to the mechanical ventilation; and marked hypercapnia and acidemia following the apnea test were found, but no test was invalidated.




J Neurol Res. 2021;11(1-2):14-19
doi: https://doi.org/10.14740/jnr646

Keywords


Brain death; Brain death protocols; Apnea test; Hypercapnia; Acidemia

Full Text: HTML PDF
 

Browse  Journals  

 

Journal of Clinical Medicine Research

Journal of Endocrinology and Metabolism

Journal of Clinical Gynecology and Obstetrics

 

World Journal of Oncology

Gastroenterology Research

Journal of Hematology

 

Journal of Medical Cases

Journal of Current Surgery

Clinical Infection and Immunity

 

Cardiology Research

World Journal of Nephrology and Urology

Cellular and Molecular Medicine Research

 

Journal of Neurology Research

International Journal of Clinical Pediatrics

 

 
       
 

Journal of Neurology Research, biannually, ISSN 1923-2845 (print), 1923-2853 (online), published by Elmer Press Inc.                     
The content of this site is intended for health care professionals.
This is an open-access journal distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License, which permits unrestricted
non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Creative Commons Attribution license (Attribution-NonCommercial 4.0 International CC-BY-NC 4.0)


This journal follows the International Committee of Medical Journal Editors (ICMJE) recommendations for manuscripts submitted to biomedical journals,
the Committee on Publication Ethics (COPE) guidelines, and the Principles of Transparency and Best Practice in Scholarly Publishing.

website: www.neurores.org   editorial contact: editor@neurores.org
Address: 9225 Leslie Street, Suite 201, Richmond Hill, Ontario, L4B 3H6, Canada

© Elmer Press Inc. All Rights Reserved.


Disclaimer: The views and opinions expressed in the published articles are those of the authors and do not necessarily reflect the views or opinions of the editors and Elmer Press Inc. This website is provided for medical research and informational purposes only and does not constitute any medical advice or professional services. The information provided in this journal should not be used for diagnosis and treatment, those seeking medical advice should always consult with a licensed physician.